Mercury 15KVA Rackmount Tower smart UPS
Mercury 1.5KVA Rackmount/ Tower smart UPS Original price was: KSh59,000.00.Current price is: KSh53,000.00. + VAT
Back to products
Mercury 3000VA Single Phase Online UPS
Mercury 3kva smart Online Tower UPS, MPM-3K Original price was: KSh105,000.00.Current price is: KSh103,000.00. + VAT

Mercury Envy 3000VA Rackmount/Tower smart UPS

Original price was: KSh95,000.00.Current price is: KSh93,000.00. + VAT

  • Mercury Envy RT II 9103S
  • 3KVA/2700W Online 72V DC
  • Rack Tower Convertible W/RAIL Kit
15 People watching this product now!
Description

Mercury Envy 3000VA Rackmount/Tower smart UPS

Mercury Envy 3000VA Rackmount/Tower smart UPS from the leading Mercury UPS dealer in Nairobi Kenya, buy online Mercury Envy 3000VA Rackmount/Tower smart UPS and have the UPS delivered at your doorstep.

Mercury Envy 3000VA Rackmount/Tower smart UPS specifications

  • Brand: Mercury
  • Model: Envy 3000VA
  • Type: Line Interactive UPS
  • Capacity: 3000VA / 2400W
  • Form Factor: Rackmount/Tower Convertible (2U),

Electrical Input

  • Voltage Range: 140V – 300V AC
  • Frequency Range: 50Hz / 60Hz ±5Hz (Auto Sensing)
  • Input Voltage: 220V AC

Electrical Output

  • Output Voltage: 220V ±10% AC
  • Frequency: 50Hz or 60Hz ±1Hz
  • Output Power Factor: 0.8
  • Waveform: Simulated Sine Wave
  • Transfer Time: Typically 4-6 ms (when switching to battery)

Battery

  • Battery Type: Sealed Lead-Acid Maintenance-Free
  • Number of Batteries: Typically 4 x 12V 9AH
  • DC Voltage: 48V DC
  • Typical Recharge Time: 4-6 hours to 90% capacity
  • Battery Backup Time: Approximately 15-30 minutes (depending on load)

Protection

  • Overload Protection: Yes
  • Short Circuit Protection: Yes
  • Over Temperature Protection: Yes
  • Battery Overcharge Protection: Yes
  • Automatic Voltage Regulation (AVR): Yes, with Boost and Buck

Indicators and Alarms

  • LED Indicators: Power On, Battery Mode, AVR, Fault
  • LCD Display: Input/Output Voltage, Battery Level, Load Level, Mode of Operation, Fault Conditions
  • Audible Alarm: Battery Mode, Low Battery, Overload, Fault

Connectivity

  • Communication Ports: USB, RS232
  • Smart Slot: Yes, for optional SNMP card
  • Software: Power management software for monitoring and control

Physical Specifications

  • Dimensions (Rackmount): (W x H x D) 438 x 86 x 508 mm (17.2 x 3.4 x 20 inches)
  • Dimensions (Tower): (W x H x D) 180 x 270 x 450 mm (7.1 x 10.6 x 17.7 inches)
  • Weight: Approximately 14 kg (30.9 lbs)

Environmental Specifications

  • Operating Temperature: 0°C to 40°C (32°F to 104°F)
  • Operating Humidity: 0-90% RH (Non-Condensing)
  • Storage Temperature: -20°C to 50°C (-4°F to 122°F)
  • Noise Level: Less than 50 dB at 1 meter

Features

  • Line Interactive Technology: Provides reliable power with automatic voltage regulation
  • Cold Start Function: Yes, allows the UPS to start on battery power alone
  • Auto Restart: Yes, automatically restarts when AC power is restored
  • Energy-Saving Features: Yes, designed for energy efficiency
  • Surge Protection: Yes, for connected equipment
  • Convertible Design: Can be used in both rackmount and tower configurations

Standards and Certifications

  • Certifications: CE, ISO9001, ISO14001
  • Compliance: IEC/EN62040-1, IEC/EN62040-2
Input Battery
Nominal Voltage 200 / 208 / 220 / 230 / 240VAC Battery Type 1KVA: 12V/9AH 1.5KVA:12V/9AH
Voltage Range 110~290VAC Numbers 2 3
Frequency 45~65Hz (Auto detect) 2KVA: 12V/9AH 3KVA:12V/9AH
Power Factor ≥0.98 4 6
Bypass Voltage Range Max.voltage: +15% Typical Recharge 4 hrs recover to 90% capacity
(Optional +5%, +10%, +25%) Time
Min.voltage: -45% Charging Current 1A (Max)
(Optional -15%, -20%, -30%) Charging Voltage 1KVA: 27.4VDC±1% 1.5KVA: 41.0VDC±1%
Frequency ±10% 2KVA: 54.7VDC±1% 3KVA: 84.1VDC±1%
Generator Input Support Mode 1KVA: RTll-BR 04009 1.5KVA: RTll-BR 06009
Output Numbers 9AH x 4 9AH x 6
Rating Voltage 200 / 208 / 220 / 230 / 240 VAC Dimensions(WxDxH) (mm) 440 x 86.5 x 430 440 x 86.5 x 430
Power Factor 0.9 Net Weight (kg) 17.3 22.3
Voltage Regulation ±1% 2KVA: RTll-BR 08009 3KVA: RTll-BR 012009
Frequency 1.Utility mode: 50/60Hz 9AH x 8 9AH x 12
(Synchronized to mains) 440 x 86.5 x 542 440 x 86.5 x 720
2.Battery mode: 50/60Hz±0.1 29 41.1
Crest Factor 3:1 Environmental
THDv Load<3% (Linear load) Capacity 1KVA 1.5KVA 2KVA 3KVA
Load<5% (Non-linear load) Input IEC320 IEC320 IEC320 IEC320
Efficiency ≥90% Connection C14-10A C14-10A C20-16A C20-16A
System Features Output IEC320 IEC320 IEC320 IEC320
Transfer time Utility to Battery: 0ms, Connection C13-10A x 6 C13-10A x 6 C13-10A x 6 C13-10A x 6
Utility to Bypass: <4ms Model/Capacity
AC Mode Load<108%~150%, 30 secs, Models ENVY RT
Load<150%, 300ms, then turn to fault Rating Capacity 1KVA 1.5KVA 2KVA 3KVA
mode & give alarm Rating Power 900W 1350W 1800W 2700W
Shipping & Delivery