Mercury Envy 3000VA Rackmount/Tower smart UPS
Mercury Envy 3000VA Rackmount/Tower smart UPS from the leading Mercury UPS dealer in Nairobi Kenya, buy online Mercury Envy 3000VA Rackmount/Tower smart UPS and have the UPS delivered at your doorstep.
Mercury Envy 3000VA Rackmount/Tower smart UPS specifications
- Brand: Mercury
- Model: Envy 3000VA
- Type: Line Interactive UPS
- Capacity: 3000VA / 2400W
- Form Factor: Rackmount/Tower Convertible (2U),
Electrical Input
- Voltage Range: 140V – 300V AC
- Frequency Range: 50Hz / 60Hz ±5Hz (Auto Sensing)
- Input Voltage: 220V AC
Electrical Output
- Output Voltage: 220V ±10% AC
- Frequency: 50Hz or 60Hz ±1Hz
- Output Power Factor: 0.8
- Waveform: Simulated Sine Wave
- Transfer Time: Typically 4-6 ms (when switching to battery)
Battery
- Battery Type: Sealed Lead-Acid Maintenance-Free
- Number of Batteries: Typically 4 x 12V 9AH
- DC Voltage: 48V DC
- Typical Recharge Time: 4-6 hours to 90% capacity
- Battery Backup Time: Approximately 15-30 minutes (depending on load)
Protection
- Overload Protection: Yes
- Short Circuit Protection: Yes
- Over Temperature Protection: Yes
- Battery Overcharge Protection: Yes
- Automatic Voltage Regulation (AVR): Yes, with Boost and Buck
Indicators and Alarms
- LED Indicators: Power On, Battery Mode, AVR, Fault
- LCD Display: Input/Output Voltage, Battery Level, Load Level, Mode of Operation, Fault Conditions
- Audible Alarm: Battery Mode, Low Battery, Overload, Fault
Connectivity
- Communication Ports: USB, RS232
- Smart Slot: Yes, for optional SNMP card
- Software: Power management software for monitoring and control
Physical Specifications
- Dimensions (Rackmount): (W x H x D) 438 x 86 x 508 mm (17.2 x 3.4 x 20 inches)
- Dimensions (Tower): (W x H x D) 180 x 270 x 450 mm (7.1 x 10.6 x 17.7 inches)
- Weight: Approximately 14 kg (30.9 lbs)
Environmental Specifications
- Operating Temperature: 0°C to 40°C (32°F to 104°F)
- Operating Humidity: 0-90% RH (Non-Condensing)
- Storage Temperature: -20°C to 50°C (-4°F to 122°F)
- Noise Level: Less than 50 dB at 1 meter
Features
- Line Interactive Technology: Provides reliable power with automatic voltage regulation
- Cold Start Function: Yes, allows the UPS to start on battery power alone
- Auto Restart: Yes, automatically restarts when AC power is restored
- Energy-Saving Features: Yes, designed for energy efficiency
- Surge Protection: Yes, for connected equipment
- Convertible Design: Can be used in both rackmount and tower configurations
Standards and Certifications
- Certifications: CE, ISO9001, ISO14001
- Compliance: IEC/EN62040-1, IEC/EN62040-2
Input | Battery | |||||
Nominal Voltage | 200 / 208 / 220 / 230 / 240VAC | Battery Type | 1KVA: 12V/9AH | 1.5KVA:12V/9AH | ||
Voltage Range | 110~290VAC | Numbers | 2 | 3 | ||
Frequency | 45~65Hz (Auto detect) | 2KVA: 12V/9AH | 3KVA:12V/9AH | |||
Power Factor | ≥0.98 | 4 | 6 | |||
Bypass Voltage Range | Max.voltage: +15% | Typical Recharge | 4 hrs recover to 90% capacity | |||
(Optional +5%, +10%, +25%) | Time | |||||
Min.voltage: -45% | Charging Current | 1A (Max) | ||||
(Optional -15%, -20%, -30%) | Charging Voltage | 1KVA: 27.4VDC±1% | 1.5KVA: 41.0VDC±1% | |||
Frequency | ±10% | 2KVA: 54.7VDC±1% | 3KVA: 84.1VDC±1% | |||
Generator Input | Support | Mode | 1KVA: RTll-BR 04009 | 1.5KVA: RTll-BR 06009 | ||
Output | Numbers | 9AH x 4 | 9AH x 6 | |||
Rating Voltage | 200 / 208 / 220 / 230 / 240 VAC | Dimensions(WxDxH) (mm) | 440 x 86.5 x 430 | 440 x 86.5 x 430 | ||
Power Factor | 0.9 | Net Weight (kg) | 17.3 | 22.3 | ||
Voltage Regulation | ±1% | 2KVA: RTll-BR 08009 | 3KVA: RTll-BR 012009 | |||
Frequency | 1.Utility mode: 50/60Hz | 9AH x 8 | 9AH x 12 | |||
(Synchronized to mains) | 440 x 86.5 x 542 | 440 x 86.5 x 720 | ||||
2.Battery mode: 50/60Hz±0.1 | 29 | 41.1 | ||||
Crest Factor | 3:1 | Environmental | ||||
THDv | Load<3% (Linear load) | Capacity | 1KVA | 1.5KVA | 2KVA | 3KVA |
Load<5% (Non-linear load) | Input | IEC320 | IEC320 | IEC320 | IEC320 | |
Efficiency | ≥90% | Connection | C14-10A | C14-10A | C20-16A | C20-16A |
System Features | Output | IEC320 | IEC320 | IEC320 | IEC320 | |
Transfer time | Utility to Battery: 0ms, | Connection | C13-10A x 6 | C13-10A x 6 | C13-10A x 6 | C13-10A x 6 |
Utility to Bypass: <4ms | Model/Capacity | |||||
AC Mode | Load<108%~150%, 30 secs, | Models | ENVY RT | |||
Load<150%, 300ms, then turn to fault | Rating Capacity | 1KVA | 1.5KVA | 2KVA | 3KVA | |
mode & give alarm | Rating Power | 900W | 1350W | 1800W | 2700W |