Mercury 6KVA Online Single Phase UPS
Mercury 6KVA Online Single Phase UPS from the leading Mercury UPS dealer in Nairobi Kenya, buy Mercury 6KVA Online Single Phase UPS and have it delivered at your doorstep.
6KVA Mercury Online UPS is a perfect balance between top performance, reliability and budget-friendly pricing, the Mercury 6KVA online UPS range has an outstanding rating. With the Mercury 6kva online UPS, you get that high-rated performance from a 4200W capacity UPS.
Mercury 6000KVA UPS rated capacity of 4200W, the Mercury 6KVA online UPS can support multiple office devices. It will deliver up to 20 minutes power backup at half load and some 7 minutes backup at full load. Powered by 20x 8.2AH 12Vbattery, the Mercury 6KVA online UPS meets the backup requirement for most small office appliances.
6000KVA Mercury UPS is designed for those organisation that doesn’t want power blackout to come between them and making money, 6KVA Mercury UPS offers investors value for their money.
Mercury 6KVA Online UPS specifications
- Brand: Mercury
- Model: 6KVA Online Single Phase UPS
- Type: Online Double Conversion UPS
- Capacity: 6KVA / 5400W
- Form Factor: Tower
Electrical Input
- Voltage Range: 110-300V AC (Single Phase)
- Frequency Range: 40Hz – 70Hz (Auto Sensing)
- Power Factor: ≥ 0.99 at full load
Electrical Output
- Output Voltage: 208/220/230/240V AC (Selectable)
- Voltage Regulation: ±1%
- Frequency: 50Hz or 60Hz ±0.1Hz
- Output Power Factor: 0.9
- Waveform: Pure Sine Wave
- Transfer Time: 0 ms (Online Mode)
Battery
- Battery Type: Sealed Lead-Acid Maintenance-Free
- Number of Batteries: Typically 16 x 12V 9AH (Internal Configuration may vary)
- DC Voltage: 192V DC
- Typical Recharge Time: 4-6 hours to 90% capacity
- Battery Backup Time: Depending on load and battery configuration
Protection
- Overload Protection: Yes
- Short Circuit Protection: Yes
- Over Temperature Protection: Yes
- Battery Overcharge Protection: Yes
- Automatic Bypass: Yes
Indicators and Alarms
- LED Indicators: Line Mode, Battery Mode, Bypass Mode, Fault, Load Level, Battery Level
- LCD Display: Input/Output Voltage and Frequency, Load and Battery Level, Mode of Operation, and Fault Conditions
- Audible Alarm: Battery Mode, Low Battery, Overload, Fault
Connectivity
- Communication Ports: RS232, USB, SNMP (Optional)
- Smart Slot: Yes, for optional communication cards
Physical Specifications
- Dimensions: (W x H x D) 260 x 717 x 570 mm (10.24 x 28.23 x 22.44 inches)
- Weight: Approximately 62 kg (136.7 lbs)
Environmental Specifications
- Operating Temperature: 0°C to 40°C (32°F to 104°F)
- Operating Humidity: 0-95% RH (Non-Condensing)
- Storage Temperature: -20°C to 50°C (-4°F to 122°F)
- Noise Level: Less than 55 dB at 1 meter
Features
Power | 6KVA / 4200W |
Voltage range | 176 ±5VAC~276 ±5VAC |
Frequency | 46~54Hz ±0.5Hz, or 56~64Hz ±0.5Hz auto sensing |
Input phase | Single phase |
Power factor | ≥0.98 |
Voltage range | 220VAC ±1% |
Output phase | Single phase |
Frequency | 50Hz ±0.2% (battery mode) |
THD | < 2% (Linear load); < 6% (non-Linear load) |
Overload | 105%~130% 10min turn to Bypass mode, > 130% 1s turn to Bypass mode |
Crest factor | 3:1 (max) |
Waveform | Pure sine wave |
Transfer time | 0ms (AC mode – Battery mode) 0ms (AC mode – Bypass mode) |
Efficiency | ≥88% |
AC mode | 5 cycles turn off inverter, no transfer to Bypass, provide alarm. |
Battery mode | 5 cycles turn off inverter, provide alarm. |
Bypass mode | Input fuse blown or break action. |
Battery Model | 12V sealed lead acid maintenance free |
DC voltage | 240VDC |
Configuration | 20x 12V/8.2AH |
Backup time | 20min (half load) / 7min (full load) |
Charge current | 1A (standard unit) / 5A (long time unit) |
Recharge time | 90% capacity after 8hrs charging |
Communication Interface | RS232; SNMP (optional) |
Parallel Port | Parallel availability for redundancy and load sharing up to three unit |
LCD Indication | Input voltage/frequency; battery voltage; output voltage/frequency; load watt/VA value & percent; inverter temperature; operation mode such as “on batt” or “on bypass” |
LED Indication | Green: normal operation; Yellow: warning condition Red: abnormal operation |
Noise level | ≤ 55dB |
Temperature | 0~40˚C; 0 ~ 40˚C (storage temperature) |
Humidity | 0~95% (non-condensing) |
Altitude | < 1500m |
Weight Net/Gross | 89/104kg (standard unit); 34/48kg (long time unit) |
Dimension (WxDxH) | 270 x 570 x 720mm |