- VGA Cables
 - USB Cables
 - Computer Accessories
 - Logitech Accessories
 - Laptop Bags
 - Vention
 - Anker Accessories
 
- Model: APC SRV3KIL
 - Type: On-Line UPS (Double Conversion)
 - Power Capacity: 3000 VA / 2700 Watts
 - Input Voltage: 230V (nominal)
 - Input Voltage Range: 160V – 300V (adjustable via settings)
 - Input Frequency: 50/60 Hz ± 5 Hz (auto-sensing)
 - Output Voltage: 230V (nominal)
 - Output Frequency: 50/60 Hz ± 1 Hz (auto-sensing)
 - Waveform Type: Sine Wave
 
Battery Specifications
- Battery Type: Sealed Lead Acid (SLA), maintenance-free
 - Battery Voltage: 12V DC (internal battery configuration)
 - Typical Runtime:
- At Full Load (2700W): Dependent on connected external battery packs
 - At Half Load (1350W): Dependent on connected external battery packs
 
 - Recharge Time: Typically 4-6 hours to 90% capacity
 - Hot-Swappable Batteries: Yes, allows for battery replacement without interrupting power
 
Physical Specifications
- Form Factor: Rackmount/Tower Convertible
 - Dimensions (Rackmount):
- Height: 2U (88.9 mm / 3.5 inches)
 - Width: 438 mm (17.2 inches)
 - Depth: 711 mm (28 inches)
 
 - Dimensions (Tower):
- Height: 445 mm (17.5 inches)
 - Width: 177 mm (7 inches)
 - Depth: 557 mm (21.9 inches)
 
 - Weight: Approximately 26 kg (57.3 lbs)
 
Output Connections
- Output Connections:
- 6 x IEC 320 C13 outlets (battery backup + surge protection)
 - 1 x Hardwire terminal block for critical load connections
 
 
Management & Communications
- Status Indicators: LCD display for detailed information on UPS status, battery condition, and power conditions
 - Audible Alarms: Yes, alarms for battery, overload, and other critical conditions
 - Communication Ports:
- USB port (for management with APC PowerChute software),
 - RS-232 port (for serial communication)
 
 - Network Management Card Slot: Yes, for optional network management card installation
 
Protection Features
- Surge Protection: Yes, protects connected devices from surges and spikes
 - Overload Protection: Yes, with automatic shutdown in case of overload
 - Short Circuit Protection: Yes
 - Automatic Voltage Regulation (AVR): Yes, corrects high and low voltage conditions
 - Cold Start Capability: Yes, allows the UPS to be powered on without mains power
 - User Replaceable Batteries: Yes
 
Environmental Specifications
- Operating Temperature: 0°C to 40°C (32°F to 104°F)
 - Storage Temperature: -15°C to 45°C (5°F to 113°F)
 - Operating Humidity: 0% to 95% non-condensing
 - Operating Elevation: 0 to 3000 meters (0 to 10,000 feet)
 
Certifications and Compliance
- Safety Approvals: IEC/EN 62040-1
 - EMC Compliance: IEC/EN 62040-2
 - Environmental Compliance: RoHS
 
	
		
	