2 Zone Fire Alarm Control Panel AW-CFP2166-2 Asenware
KSh23,000.00 Original price was: KSh23,000.00.KSh22,000.00Current price is: KSh22,000.00. + VAT
AW-CFP2166 series conventional fire alarm panel is designed based on EN54 part 2&4 standard.
2. It is modularized design, the panel can extend from 1 zone to 32 zones easily.
3. It has 2 level control mode by a lock
4. It has 24VDC and 5VDC power supply output.
5. It has FIRE and FAULT signal output.
6. It has 2 general sounders output.
7. Each zone has 1 circuit detectors input.
8. Each zone can be disable by a button.
9. It has RESET button to reset the panel.
10. It has SILENCE button to stop BUZZER and SOUNDERS.
11. It has EVACUATE button to start a manual fire alarm immediately.
12. It has battery low protection function, when battery voltage lower than 21VDC, battery will be cut off automatically until the mains power is on.
18
People watching this product now!
Description
2 Zone Fire Alarm Control Panel AW-CFP2166-2 Asenware Mall+254
2 Zone Fire Alarm Control Panel AW-CFP2166-2 Asenware series conventional fire alarm panel is designed based on EN54 part 2&4 standard. And it is the central part of conventional fire alarm system, designed for applications requiring smoke detector, bell, manual pull stations, and sprinkler supervision. Each zone can be disabled by a button. The basic unit offers 1 to 8 zones of initiation, up to 16 zones for larger applications.
Asenware 2 Zone Fire Alarm Control Panel has 2 level control mode by a lock, fire and fault signal output, optical GSM module for fire alarm by SMS, 2 general sounders output, battery low protection function, silence button to stop buzzer and sounders, each zone can be disable by a button, battery not included.
AW-CFP2166-4 is a typical one zone fire alarm control panel which is designed based on EN54 part 2 & 4 standard. It is the heart of the fire automatic alarm system, which can realize centralized control, can supply power to the detectors, manual call point, bell and more. One zone of the panel can match with 20 pieces fire alarm system accessories.
Asenware 2 Zone Fire Alarm Control Panel fire alarm system wire drawing is for reference. Fire alarm control panels are designed to fulfill the requirements of EN54 parts 2 & 4 as well as being easy to install, operate and maintain. Being of modular construction
Asenware 2 Zone Fire Alarm Control Panel specifications
ITEM | 1Zone panel | 2Zone panel | 4-16 Zone panel | 4-32 Zone panel |
Photo | ||||
Model No. | AW-CFP2166-01 | AW-CFP2166-02 | AW-CFP2166-04-16 | AW-CFP2166-04-32 |
Power specification | ||||
Mains supply voltage | 110VAC or 240VAC | |||
Internal power supply | 27.2VDC | |||
Total output current limited | 500mA @ 240VAC | 500mA @ 240VAC | 3A @ 240VAC | 3A @ 240VAC |
Main supply monitor for fault | Yes | |||
Battery protection for low voltage | Yes | |||
Batteries (default configuration) | 12V2AH*2 | |||
Detector circuit specification | ||||
Number of circuit | 1 | 2 | 4-16 | 4-32 |
Line fault monitor for open circuit | Yes | |||
Line fault monitor for short circuit | Yes | |||
Line fault monitor for detector removal | Yes, if End of Line Monitor Unit fitted in place of End of Line Resistor | |||
End of Line device | 6.8k Ω , 5% tolerance, 0.25W (colour code-blue, grey, red, gold) | |||
Detector continuity diodes | Silicon 1N4001 or Schottky type (required if End of Line Monitor Unit fitted to give Detector Removal Fault) | |||
Call point resistor value | 470 to 680 Ω , 0.225 or 0.5 watt | |||
Maximum number of smoke/heat detectors per zone | 20 (based on a total detector current of 2mA, each detector consuming 100μ A). Note: if End of Line Monitor Unit is fitted, for correct operation maxmum voltage drop must not exceed 12 volts. | |||
Maximum number of manual call points per zone | No limit | |||
Sounder circuit specification | ||||
Number of general circuits | 2 | |||
End of line resistor value | 6.8k Ω , 5% tolerance, 0.25W (colour code-blue, grey, red, gold) | |||
Line fault monitor for open circuit | Yes | |||
Line fault monitor for short circuit | Yes | |||
Outputs fused AT | 400mA | |||
Maximum number of bells @ 20mA of each sounder output | 20 | |||
Fuses | ||||
Battery fuse | 1.5A F 20mm | |||
Sounder outputs | 500mA F 20mm | |||
Fire and fault output | ||||
Output type | NC and NO relay | |||
Maximum current | 100mA | |||
Connection block | ||||
Largest acceptable conductor size | 2.5mm 2 | |||
Smallest acceptable conductor size | 0.75mm 2 | |||
Size and weight | ||||
Dimensions(mm) | 272*200*70mm | 320*231*90mm | 395X502X124 | 362X565X124 |
Weight (without batteries) | 4kg | 5kg | 7kg | 8kg |
Weight (with batteries) | 5.8kg | 6.8kg | 9.6kg | 12.5kg |
Reviews (0)
Be the first to review “2 Zone Fire Alarm Control Panel AW-CFP2166-2 Asenware”
You must be logged in to post a review.
Shipping & Delivery
Related products
Electric strike lock long chase
Rated 0 out of 5
LH4000 RFID ZKTeco Smart Hotel Door Lock System
Rated 0 out of 5
RL-3915 Melody rings doorbell
Rated 0 out of 5
Walk Through Metal Detector
Rated 0 out of 5
- The system has the function of displaying environmental monitoring data; High performance, high sensitivity and high stability
- Equipped with system networking, able to manage multiple devices through 1 PC (optional)
- Preset the weight, volume, size, location, key, jewelry, belt buckle and other false alarms of metal items
- It complies with EMC electromagnetic radiation standard and adopts weak magnetic field technology, which is harmless to pacemaker wearers, pregnant women, sight, film and instant belt
ZK Access TF1700 Outdoor Biometric & Card Reader
Rated 0 out of 5
- Rugged structure for outdoor installation and extra durability
- IP65 rated waterproof and weatherproof structure
- Slim and elegant design
- One of the world’s smallest fingerprint terminals
- Sleek and slim design for narrow spaces.
- Fast and accurate fingerprint algorithm
- Fingerprint identification in 1 second
ZKteco FR1200-ID fingerprint reader
Rated 0 out of 5
ZKTeco ZK F16 Outdoor Fingerprint Reader
Rated 0 out of 5
ZKteco ZK MA300 Stainless Fingerprint Reader Outdoor
Rated 0 out of 5
ZKteco ZK MA300 Stainless Fingerprint Reader Outdoor, one of the innovative biometric fingerprint readers for access control applications. Offering unparalleled performances by adopting an advanced ZK fingerprint algorithm for reliability, precision and excellent matching speed. It is metallic casing and IP65 rated
Reviews
There are no reviews yet.